Use this free calculator (beta) to compare Benchmark’s STB-1 Structural Thermal Break and TBF High Density Thermal Break pads for a connection. Enter the plate size, sustained load and temperature difference to see heat flow through the pad, the reduction compared with solid steel, bearing stress, and, for STB-1, elastic and long-term deflection against the 5% creep limit.
For preliminary comparison only. Heat flow is one-dimensional through the pad itself (bolts, plates and surrounding details not included). STB-1 values: k = 1.055 BTU·in/hr·ft²·°F, compressive strength 48,000 psi, compressive modulus 830,000 psi (1" thick), long-term deflection 1.25 × elastic up to 2,000 psi, creep and permanent set limit 5% of thickness. TBF values: k = 0.32 / 0.38 / 0.53 and published compressive stress 560 / 1,100 / 2,150 psi. Final connection design is the responsibility of the engineer of record.
Related: STB-1 structural thermal break systems · thermal break washers and bushings · resources for engineers and architects · structural thermal break design guides and tools
Send us your connection drawings, bolt schedule or load requirements and we will quote STB-1, TBF, washers and bushings cut and machined to your specification. Call 800-580-4195 or use the form below.