Canada flag
United States flag

Thermal Break Calculator

Use this free calculator (beta) to compare Benchmark’s STB-1 Structural Thermal Break and TBF High Density Thermal Break pads for a connection. Enter the plate size, sustained load and temperature difference to see heat flow through the pad, the reduction compared with solid steel, bearing stress, and, for STB-1, elastic and long-term deflection against the 5% creep limit.

BETAThis calculator is a beta version. It is still being tested and refined, and results may change as it is updated. Use it for preliminary comparison only; it is not a substitute for a connection design by the engineer of record. Found an issue? Let us know.

Inputs

Thermal results

Structural results

For preliminary comparison only. Heat flow is one-dimensional through the pad itself (bolts, plates and surrounding details not included). STB-1 values: k = 1.055 BTU·in/hr·ft²·°F, compressive strength 48,000 psi, compressive modulus 830,000 psi (1" thick), long-term deflection 1.25 × elastic up to 2,000 psi, creep and permanent set limit 5% of thickness. TBF values: k = 0.32 / 0.38 / 0.53 and published compressive stress 560 / 1,100 / 2,150 psi. Final connection design is the responsibility of the engineer of record.

How the Calculator Works

  • Heat flow through the pad is Q = k × A × ΔT ÷ t, using the pad’s thermal conductivity k, area A, temperature difference ΔT and thickness t. The steel comparison uses k = 374.5 BTU·in/hr·ft²·°F for the same geometry.
  • Bearing stress is the sustained compressive load divided by the bearing area. Enter the effective bearing area from your connection analysis, or leave it blank to use the full plate.
  • Elastic deflection is stress × thickness ÷ compressive modulus (830,000 psi for STB-1).
  • Long-term deflection is 1.25 × elastic deflection, valid for bearing stresses up to 2,000 psi, checked against the design limit of 5% of the original thickness.

Related: STB-1 structural thermal break systems · thermal break washers and bushings · resources for engineers and architects · structural thermal break design guides and tools

Request a Quote or Data Sheet

Send us your connection drawings, bolt schedule or load requirements and we will quote STB-1, TBF, washers and bushings cut and machined to your specification. Call 800-580-4195 or use the form below.