Home

TBF High Density Thermal Break: 3 Grades, Stocked in Canada

TBF High Density Thermal Break is a rigid, lightweight thermal break for connections where insulation value matters more than load. It has up to 3.3 times the R-value per inch of STB-1, and comes in three grades so you can match compressive strength to the load. We stock TBF in 1″, 2″ and 3″ thicknesses in Canada and cut it to size in-house, with production in as little as 3 days.

Comparing grades or deciding between TBF and STB-1? See the full TBF grade guide and what a structural thermal break is and where each material fits.

TBF high density thermal break

TBF High Density Thermal Break

Available in 3 densities: TBF-150, TBF-200 and TBF-280

Why TBF

  • High R-value for the cost, up to R-3.1 per inch.
  • Lightweight and does not rust.
  • Works with a wide range of adhesives and grouts.
  • Can help projects earn LEED points for energy performance.

Contact us

TBF Thermal Break Model Density (LB/FT3) EN 1602 / ASTM D1622 Compressive Stress (PSI) Thermal Conductivity, k (BTU-in/hr-ft2-F) R-Value per Inch Operating Temperatures (F) Fire Behavior
TBF-150 15.0 560 0.32 3.1 -328 / +176 DIN 4102 Class B3
TBF-200 20.0 1,100 0.38 2.6 -328 / +176 DIN 4102 Class B3
TBF-280 28.0 2,150 0.53 1.9 -328 / +176 DIN 4102 Class B3

Benchmark accepts no responsibility for individual results obtained. Everyone is strongly recommended to verify data and obtain their own independent test results. This data is subject to change without notice.

All grades are stocked in 1″, 2″ and 3″ thicknesses. The compressive stress is the published value; divide it by your safety factor to get the design bearing stress. NOTE: TBF High Density should not be used in moment connections.

Typical applications for TBF

  • Structural column bases: between steel base plates and concrete footings in heated buildings.
  • Cold storage and freezer foundations: isolating the cold floor from the foundation, down to −328°F.
  • Roof anchors, HVAC curbs and equipment supports: heat transfer points through the roof.
  • Foundation and slab connections: where slab edges and footings meet the envelope.
  • Isolation blocks: thermal blocks under lightly loaded equipment and framing.

TBF or STB-1?

Use TBF when loads are light and insulation value comes first. Use STB-1 Structural Thermal Break when the connection carries high loads or moment.

TBFSTB-1
Compressive strength560–2,150 psi48,000 psi
R-value per inch1.9–3.10.95
Moment connectionsNoYes
Best forColumn bases, cold storage, light loadsShear and moment connections, canopies, balconies

Comparing TBF to Armatherm 500? See the grade-for-grade comparison.

How to choose a TBF grade

  1. Find the bearing stress. Divide the sustained load by the bearing area of the plate.
  2. Apply your safety factor. Divide each grade’s compressive stress by the safety factor your engineer uses.
  3. Pick the lightest grade that works. Lower grades insulate better: TBF-150 gives R-3.1 per inch, TBF-280 gives R-1.9. If even TBF-280 isn’t enough, or the connection carries moment, use STB-1.
  4. Pick the thickness. 1″, 2″ or 3″. Thicker pads insulate more; your designer sets the thickness for the assembly.

Free tools for each step:

Results are estimates; verify the final design with your engineer or designer.

TBF FAQ

What is TBF High Density Thermal Break?

A rigid, lightweight thermal break made for lightly loaded connections where insulation value comes first. It comes in three grades: TBF-150, TBF-200 and TBF-280.

Which TBF grade should I use?

The lightest grade whose compressive stress, divided by your safety factor, still exceeds the bearing stress. Lighter grades insulate better. The TBF Grade Selector does the check for you.

Can TBF be used in moment connections?

No. Use STB-1 Structural Thermal Break for moment connections and high loads.

What R-value does TBF have?

R-3.1 per inch for TBF-150, R-2.6 for TBF-200 and R-1.9 for TBF-280.

What thicknesses do you stock?

1″, 2″ and 3″. We cut pads to size in-house.

Can TBF be used in freezers and cold storage?

Yes. TBF is rated from −328°F to +176°F and is commonly used to isolate cold storage and freezer foundations.

How fast can I get TBF?

TBF is stocked in Canada, with production in as little as 3 days.

Can TBF be glued or grouted?

Yes. TBF works with a wide range of adhesives and grouts. Check compatibility with the product you plan to use.

Additional thermal isolation and vibration control products we stock in Canada for fast fabrication and shipment:

Yellow thermal break bushings and grey thermal break washers

Thermal Break Washers and Bushings

White STB structural thermal break pads with thermal break bushings and washers

Structural Thermal Break

TBF High Density Thermal Break

Two-plate slide bearing with graphite sliding surface

Custom Slide Bearing Pads

Request a quote

Tell us the product, sizes and quantity, or attach your drawing. We come back with price and lead time.