Canada flag
United States flag

TBF Grade Selector

TBF High Density Thermal Break comes in three grades: TBF-150, TBF-200 and TBF-280. Higher grades carry more load but conduct more heat, so the best choice is usually the lightest grade that meets your engineer’s safety factor. Use this free selector (beta) to compare all three grades for your connection.

Inputs

Grade comparison

GradePublished compressive stressFactor vs. your stressMeets required factor?Heat flow

For preliminary grade selection only. TBF published compressive stress: TBF-150 560 psi, TBF-200 1,100 psi, TBF-280 2,150 psi; thermal conductivity 0.32 / 0.38 / 0.53 BTU·in/hr·ft²·°F. TBF should not be used in moment connections. Heat flow is one-dimensional through the pad only.

How the Selector Works

  • Bearing stress is the sustained compressive load divided by the bearing area. Enter the effective bearing area from your connection analysis, or leave it blank to use the full plate.
  • Factor for each grade is its published compressive stress divided by your bearing stress, checked against the safety factor your engineer requires.
  • Heat flow through the pad is k × A × ΔT ÷ t for each grade, so you can see the thermal cost of a stronger grade.
  • Above TBF’s range? STB-1 Structural Thermal Break handles much higher bearing stresses.

TBF is stocked in 1″, 2″ and 3″ thicknesses. See TBF High Density Thermal Break for full specifications.

Related design tools: Thermal Break Calculator  ·  Thermal Washer & Bushing Selector  ·  Thermal Break Heat Loss & Savings Calculator  ·  Condensation & Dew Point Checker  ·  All thermal break tools  ·  All engineering design tools

Products: STB-1 Structural Thermal Break  ·  TBF High Density Thermal Break  ·  Thermal break washers and bushings

Request a Quote or Data Sheet

Send us your connection drawings, bolt schedule or load requirements and we will quote STB-1, TBF, washers and Thermal Bushings cut and machined to your specification. Call 800-580-4195 or use the form below.

BETAResults are estimates only. Verify them with your engineer or designer before proceeding. Found an issue? Let us know.