TBF vs Armatherm 500: grade-for-grade comparison

PropertyTBF-150Armatherm 500-150TBF-200Armatherm 500-200TBF-280Armatherm 500-280
Compressive stress (psi)5605601,1001,1002,1502,150
Compressive modulus (psi)18,13018,13029,00029,00049,31049,300
Thermal conductivity, k (BTU·in/hr·ft²·°F)0.320.320.380.390.530.53
R-value per inch3.13.12.62.61.91.9
Density (lb/ft³)15—20—28—

Armatherm values from the published Armatherm 500 Series data sheet (V3). TBF values from the TBF High Density Thermal Break data sheet, Rev. 10. “—” means not published. Values are typical, not specification limits; confirm with the engineer of record.

Availability and service

TBF (Benchmark)Armatherm 500
Stock thicknesses½”, ¾”, 1″, 2″ and 3″½”, 1″ and 2″
Operating temperature−328 to +176 °F−300 to +175 °F
ProductionAs little as 3 daysContact supplier
FabricationCut, drilled and machined in-house to your drawingsContact supplier
ManufacturerBenchmark, CanadaArmadillo Noise & Vibration

Choosing the right TBF grade

Choose the lowest density that carries your design bearing stress with an appropriate safety factor. Lower density gives a higher R-value per inch; higher density carries more load and deflects less.

  • TBF-150: lighter loads where insulation value governs, such as roof anchors and HVAC supports
  • TBF-200: general use for column bases, slab edges and isolation blocks
  • TBF-280: higher bearing loads, such as heavily loaded column bases and freezer foundations

TBF is for compression-bearing connections and should not be used in moment connections. For moment or shear connections, see STB-1 Structural Thermal Break.

Typical applications

  • Structural column bases
  • Cold storage and freezer foundation isolation
  • Roof anchors, HVAC supports and other heat transfer points
  • Foundation and slab connections
  • Isolation blocks