Download the Vibsorb PTFE technical data sheet and Safety Data Sheet (SDS) in English or French. Each PDF package contains the one-page technical data sheet for unfilled and 25% glass-filled PTFE and the 16-section SDS for Vibsorb PTFE 25% glass filled, prepared in the WHMIS 2015 / GHS format. Benchmark manufactures and cuts Vibsorb PTFE in Canada as raw and finished sheet, rod, PTFE slide bearings, etched PTFE and machined parts.

Typical properties of Vibsorb PTFE

PropertyASTM / ULUnitVibsorb PTFE (unfilled)Vibsorb PTFE (25% glass)
Physical
Specific gravityD792–2.14 – 2.202.25
Water absorption, 24 hD570%< 0.010.02
Mechanical
Tensile strengthD638MPa (psi)20 – 35 (2,900 – 5,080)14.5 (2,100)
Tensile modulusD638MPa (psi)562 (81,500)–
Elongation at breakD638%210 – 400270
Flexural strengthD790MPa (psi)No break13.4 (1,950)
Flexural modulusD790MPa (psi)496 (72,000)1,310 (190,000)
Compressive strength at 1% deformationD695MPa (psi)4.0 – 4.5 (580 – 650)10.8 (1,560)
Compressive modulusD695MPa (psi)483 (70,000)758 (110,000)
Deformation under load, 14 MPa, 24 hD621%10 – 15–
HardnessD2240Shore D50 – 6060
Izod impact, notchedD256J/m (ft-lb/in)187 (3.5)–
Friction
Coefficient of friction, staticD3028–0.05 – 0.08–
Coefficient of friction, dynamicD3028–0.04 – 0.06–
PTFE on steel, oil lubricated––0.022–
Thermal
Working temperature range–°C (°F)−240 to +260 (−400 to +500)
Melting pointD3418°C (°F)327 (621)
Heat deflection temperature, 0.45 MPa (66 psi)D648°C (°F)121 – 140 (250 – 284)–
Heat deflection temperature, 1.82 MPa (264 psi)D648°C (°F)55 (132)65 (150)
Coefficient of thermal expansion, 25 – 100 °CD69610⁻⁵/°C (10⁻⁵/°F)13.5 (7.5)11.5 (6.4)
Thermal conductivityC177W/m·K (BTU·in/ft²·h·°F)0.25 (1.70)0.45 (3.1)
Specific heat–J/g·K1.0–
Flammability ratingUL94–V-0
Electrical
Dielectric strength, 0.5 mm (short time)D149kV/mm (V/mil)55 (1,400)–
Dielectric strength, 3.2 mm (short time)D149kV/mm (V/mil)11.2 (285)–
Dielectric constant, 1 MHzD150–2.12.4
Dissipation factor, 1 MHzD150–< 0.00020.05
Volume resistivity, 50% RHD257Ω·cm> 1017> 1015
Surface resistivityD257Ω> 1015–

Typical values at 23 °C (73 °F) unless stated; not for specification purposes. A dash (–) means not tested or not published. D621 is a superseded standard. Friction measured at 5 m/min sliding speed, 0.1 MPa contact pressure, steel counterface Ra 0.4 – 0.6 µm.

Safety Data Sheet (SDS) summary – Vibsorb PTFE 25% glass filled

Product identification

Product: Vibsorb PTFE 25% Glass Filled (sheet, rod, cut-to-size bearings and machined shapes). Recommended use: slide bearings, bearing pads, wear strips, seals and machined industrial parts. Supplier: BENCHMARK Group of Companies, 800.580.4195, cs@bmssi.ca.

Hazard identification (WHMIS 2015)

Not classified as a hazardous product in the form supplied (solid manufactured article). No pictogram, signal word or hazard statement is required. NFPA / HMIS: Health 1, Flammability 1, Reactivity 0. Dust from cutting or machining contains glass fibre and can irritate the eyes, skin and respiratory tract. Heating above 260 °C (500 °F) releases fumes that can cause polymer fume fever; thermal decomposition products include hydrogen fluoride.

Composition

ComponentCAS No.Weight %
Polytetrafluoroethylene (PTFE)9002-84-070 – 80
Glass, oxide, chemicals (glass fibre)65997-17-320 – 30

First aid

Inhalation: move to fresh air; seek medical attention if symptoms persist. Skin: wash with soap and water. Eyes: flush with water for at least 15 minutes. Fumes from overheated material can cause flu-like symptoms that usually resolve within 48 hours.

Fire-fighting

The product does not support combustion (UL94 V-0). Use media suitable for the surrounding fire. Above 300 °C (572 °F) decomposition can form hydrogen fluoride, carbonyl fluoride and carbon monoxide; firefighters should wear SCBA.

Handling, storage and exposure controls

Avoid creating dust and heating above 260 °C (500 °F); use local exhaust ventilation when machining. Do not smoke in work areas. Store in a cool, dry, ventilated area. Glass fibre exposure limits (Alberta OHS Code and ACGIH): 1 f/cc respirable fibres, 5 mg/m³ inhalable. Wear safety glasses, work gloves and, where dust may exceed limits, a NIOSH N95/P100 respirator selected per CSA Z94.4.

Physical properties, stability and toxicology

Off-white to light tan solid, odourless; melting point 327 °C (621 °F); specific gravity 2.20 – 2.26; insoluble in water. Stable under normal conditions; reacts with molten alkali metals and with finely divided aluminium and magnesium above 425 °C. Low toxicity as a solid; neither PTFE nor continuous filament glass fibre is classified as a carcinogen (IARC Group 3).

Transport, disposal and regulatory

Not regulated for transport under TDG, US DOT, IATA or IMDG. Not a hazardous waste in its original form; clean scrap can be recycled. Components are listed on Canada’s Domestic Substances List and the US TSCA Inventory.

This summary is for reference only. Always refer to the full SDS in the download above.

PTFE data sheet and SDS – frequently asked questions

Is PTFE a hazardous product under WHMIS?

No. Vibsorb PTFE sheet, rod and machined parts are solid manufactured articles and are not classified as hazardous in the form supplied. The SDS covers dust from machining and fumes from overheating above 260 °C (500 °F).

Is the SDS available in French?

Yes. The French package (fiche technique et fiche de données de sécurité, SIMDUT 2015) is available as a free download on this page.

What temperature range can Vibsorb PTFE handle?

Vibsorb PTFE works from −240 °C to +260 °C (−400 °F to +500 °F) and melts at 327 °C (621 °F).

What is the coefficient of friction of PTFE?

Unfilled Vibsorb PTFE has a static coefficient of friction of 0.05 – 0.08 and a dynamic coefficient of 0.04 – 0.06 (ASTM D3028). On oil-lubricated steel it is about 0.022.

Should I use unfilled or glass-filled PTFE for slide bearings?

Unfilled PTFE gives the lowest friction. 25% glass-filled PTFE is stiffer and stronger in compression (10.8 MPa / 1,560 psi at 1% deformation versus 4.0 – 4.5 MPa for unfilled), so it is used for higher bearing pressures. See our PTFE slide bearings page or contact us for help choosing.